White-Rodgers™ Blue™ Digital Programmable Thermostat, Touchscreen, 45 to 99 deg F Control Range, Heat/Cool Differential, 1 Stages Heat, 1 Stages Cool, Programs Per Week: 7/5+1+1, Terminal Designations: RC, RH, C, W/E, Y, O/B, G, L, 6, +, S, -, System Switching: Heat/Off/Cool, Fan Switching: Auto, 12 sq-in Lighted Display, 20 to 30 VAC, Battery/Hardwire, White, 4-9/16 in H x 5-13/16 in W x 1-13/16 in D, Import
Color |
: |
White |
Control Range |
: |
45 to 99 deg F |
Differential |
: |
Heat/Cool |
Dimensions |
: |
4-9/16 in H x 5-13/16 in W x 1-13/16 in D |
Display |
: |
12 sq-in Lighted |
Domestic/Import |
: |
Import |
Fan Switching |
: |
Auto |
Power Source |
: |
Battery/Hardwire |
Programs per Week |
: |
7/5+1+1 |
Stages Cool |
: |
1 |
Stages Heat |
: |
1 |
System Switching |
: |
Heat/Off/Cool |
Terminal Designations |
: |
RC, RH, C, W/E, Y, O/B, G, L, 6, +, S, - |
Type |
: |
Touchscreen |
Voltage Rating |
: |
20 to 30 VAC |
Warranty |
: |
5 Years |
- Universal models quickly configure for single stage, multi-stage or heat pumps and heat pumps dual fuel system - programmable or non-programmable
- Easy reader model is easy to read and easy to use
- Commercial offers occupied damper or economizer control and locking cover and subbase
- Staging control for nearly all conventional and heat pumps system
- Single stage model compatible with all single stage systems low voltage 750 mV and 3 wires zone system
- Heat pumps dual fuel options eliminate the needs for a fossil fuel kit
- Automatic changeover options
- Program fan options
- Keypad lockout and set point temperature limits options
- Indoor remote sensor for averaging options
- Outdoor remote sensor options on select universal models for outdoor temperature readings and dual fuel balance points or outdoor thermostat function (select models)
- Dual power hardwired and/or battery or tripower hardwired and/or battery with system assist
- Energy management recovery
- Set points temperature limits adjustable maximum and minimum
- 0.4 deg F fast, 0.6 deg F medium and 1.2 deg F heat differentials
- 0.9 deg F fast, 1.2 deg F medium and 1.7 deg F slow cool differentials
- 0.9 deg F fast, 1.2 deg F medium and 1.7 deg F slow heat pumps differentials
- 32 to 105 deg F operating ambient
- For gas oils, electric application, 3 wires zone valves, millivolt compatible
- 1 mV to 30 VAC/DC
-