The ICM287 control is microprocessor based using software to determine the sequence of operation and timing. The control also monitors the status of the gas valve before energizing the inducer and heat and cool blowers.
ICM™ by Packard Furnace Control Board, 120 VAC Input, 24 VAC 60 Hz, Domestic
- Controls inducer and blower control
- Microprocessor-based
- Designed for 100% gas shutoff in case of ignition failure
- Monitors timing and gas valve
- 24 VAC at 60 Hz control voltage
- 30 A resistive at 120 VAC cool blower
- 10 A resistive at 120 VAC heat blower
- 10 A resistive at 120 VAC inducer blower
- Direct Replacement For Goodman B18099-04