1. pin-int

McDonnell & Miller 144692

McDonnell & MillerRB-24E Electronic Low Water Cut-Off, 2.5 VA, 2 A at 24 VAC, 160 psi, Import

  • Manufacturers: Xylem
  • Brand Name: McDonnell & Miller
  • Part#: 282991
  • MPN: 144692
  • UPC: 751875446928
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Company Availability: loading branchavailability

McDonnell & MillerLow Water Cut-Off, Electronic, Series: RB-24E, 2.5 VA, 2 A at 24 VAC Switching Capacity, 160 psi, 5-3/4 in L x 1-7/8 in W, Import

Dimensions      :      5-3/4 in L x 1-7/8 in W
Domestic/Import      :      Import
Power Consumption      :      2.5 VA
Pressure Rating      :      160 psi
Series      :      RB-24E
Switching Capacity      :      2 A at 24 VAC
Type      :      Electronic
Warranty      :      1 Year from the Date of Installation or 2 Years from the Date of Manufacture
  • Brass threads provide a metal-to-metal seal that ensures a leak-free installation
  • Integrated wrench flats enable secure installation without damage to the housing
  • McDonnell & Millers patented self-cleaning probe minimizes scale build-up and extends the recommended cleaning interval to 5 years
  • Plug & Play wiring harnesses are available for most residential gas-burning boilers
  • Universal wiring harness fits 100% of today's gas boilers
  • Compact size
  • Easy to install and wire
  • Automatic reset feature resumes operations after a power outage when water is on probe
  • Green LED indicating power is on
  • Red LED indicating low water condition
  • Solid state operation
  • 15,000 ohms probe sensitivity
  • Maximum ambient temperature 120 deg F (49 deg C)
  • Maximum water temperature 250 deg F (121 deg C)
  • Maximum water pressure of 160 psi (11.2 kg/cm-sq)
  • 3/4 in connections
  • pdfBrochure https://www.capitolgroupinc.com//ASSETS/DOCUMENTS/ITEMS/EN/Xylem_144692_Brochure.pdf
  • pdfCatalog-1 https://www.capitolgroupinc.com//ASSETS/DOCUMENTS/ITEMS/EN/Xylem_126400_Catalog.pdf
  • pdfData/Spec Sheet-1 https://www.capitolgroupinc.com//ASSETS/DOCUMENTS/ITEMS/EN/Xylem_144692_Data_Sheet.pdf
  • pdfInstruction/Installation Sheet https://www.capitolgroupinc.com//ASSETS/DOCUMENTS/ITEMS/EN/Xylem_144692_Instruction_Installation.pdf