Air filters are designed for dust holding, pressure drop and MERV rating. Flanders' Pre-Pleat® 40 LPD achieves the highest dust holding capacity and the lowest pressure drop in the industry, while maintaining a mechanical MERV 8A per ASHRAE Standard 52.2.
Flanders® Pre-Pleat® 40 LPD Pleated Air Filter, Standard Capacity, Series: 80055, 20 in Width, 2 in Depth, 25 in Height, MERV: MERV 8A, 1736 cfm, 180 deg F, 1 in WG Final Resistance, Non-Woven Synthetic Media, 24-1/2 in H x 19-1/2 in W x 1-3/4 in D, Domestic
Depth |
: |
2 in |
Domestic/Import |
: |
Domestic |
Final Resistance |
: |
1 in WG |
Flow Rate |
: |
1736 cfm |
Height |
: |
25 in |
MERV |
: |
MERV 8A |
Media Material |
: |
Non-Woven Synthetic |
Overall Dimensions |
: |
24-1/2 in H x 19-1/2 in W x 1-3/4 in D |
Series |
: |
80055 |
Temperature Rating |
: |
180 deg F |
Type |
: |
Standard Capacity |
Width |
: |
20 in |
- Ecologically friendly filtration: medium frame components made from recyclable materials
- Expanded metal grid prevents media flutter while in operation
- Media maximixing V-pleat design
- Great frame strength due to diagonal and horizontal support members as well as wire backed media
- Filter media pack is sealed to eliminate air bypass
- 100 percentage synthetic non-woven, proprietary media that can be recycled
- Engineered with a gradient density composition achieving a MERV 8A using the mechanical method of particle capture
- Media does not rely on an electrostatic charge to capture particulate which will dissipate over time and during use
- Newly designed expanded metal is continuously laminated on the air leaving side to provide pleat stability while eliminating flutter during operation
- V-pleat design aids in pressure drop while reducing energy cost and design allows for maximum airflow and dust holding capacity during the life of the filter
- Heavy duty, two piece, moisture-resistant frame includes diagonal and horizontal support members bonded to the media on the air entering and exiting sides for unsurpassed frame strength and Interlocking corners and positive media-to-frame seal reduce the possibility of air bypass
- PD represents pressure drop in inches WG
- The recommended final pressure drop for all models is 1 in WG
- System design may dictate a lower change out point
- Efficiency is not affected by the conditioning steps outlined in ASHRAE 52.2-2007
- 1042 cfm at 300 fpm, 1736 cfm at 500 fpm
-
Brochure
https://www.capitolgroupinc.com//ASSETS/DOCUMENTS/ITEMS/EN/Flanders_10155-011010_Brochure.pdf